1, maximum drain-source voltage (VDSS): 650 V.
2. Maximum leakage current (ID): 12A.
3. Maximum power consumption (PD): 200 W.
4. Static drain-source resistance (RDS (ON)): 0.5 Ω.
If substitution is needed, the following aspects need to be considered:
1, maximum drain-source voltage (Vdss): We need to choose a device with higher voltage than the original device to replace it.
2. Maximum drain current (Id): Devices with the same or higher current tolerance should be selected.
3. Maximum power consumption (Pd): Devices with the same or higher power tolerance should be selected.
4. Static drain-source resistance (Rds(on)): devices with the same or lower resistance value need to be selected.