Connect the external line to the external board of your switch and connect the employee's phone to your extension board. When you dial the outside line of the switch again, the customer will hear a voice prompt: please dial the extension number, and please dial 0 to check the number. Extension numbers are built into the system. Whoever dials the extension number will ring. If you dial 0,800, the switchboard will ring. Call whoever you want. The initialization state is generally like this. If you need to change the extension number, incoming mode, grade, etc. . . . Just do the corresponding operation in the software. Your question is so general that I can only answer you like this. You can keep asking any questions.
Question 2: How to set the extension number requires the use of a switch wire, which is as simple as installing a power socket and there is no danger. All information can be bought in the business hall of the telecommunications department. The setting of program-controlled telephone exchange is slightly different. Generally speaking, the ports of a switch are divided into external ports and internal ports. As the name implies, the external port is connected to the external line and the internal port is connected to the telephone. When leaving the factory, the general system has an extension number by default (the default extension number produced by different manufacturers is different). For example, the first outgoing call is 80 1 and the second incoming call is 802. By analogy, an extension can make internal calls by directly dialing the extension number. When an extension wants to dial an outside line, it usually takes a code to dial an outside line (the general code is 0 or 9). When the outside line enters, it can be set to manual duty or computer duty mode. See the instructions for specific operation methods.
Question 3: How to set the extension number of SPC telephone exchange? After the extension number is connected to the switch, there is a default extension number which can be changed by programming. Specific operation needs to refer to the manual for setting.
You can only answer the phone, not dial. It may be that the level of permission setting is different. Now all switches have the function of setting permissions to control company costs.
Question 4: How to set up the company telephone extension? First of all, determine the brand and model of a telephone exchange used by your company. Because each exchange is set in a different way, you need the landlord to provide accurate information. . . Please call 029-86354650 directly if necessary.
Question 5: How to set the extension number format of the telephone exchange: * 2 6 abc # Note: "abc" is the current number of the extension. When the first extension on duty is busy, the user dials "0" to switch to the second extension on duty.
For example, set 806 as the second on-duty extension: lift extension 80 1 unlock-enter "* 26806 #"-beep-hang up extension 80 1 Note: when the first and second on-duty extensions are busy, if there is an outside call to the on-duty extension, the system will choose one between 802 and 808. But the extension call is not transferred, and the prompt tone is busy directly.
By default, the first responsibility range is 802 and the second responsibility range is 803.
Question 6: How is the general telephone extension number set? I don't know what you mean. Each model is different. The status of domestic factories is generally 800. 80 1 。 802。 . . . . .
Question 7: How to set the extension of the telephone exchange? 10 branch telephone exchange is also called program-controlled exchange, and the setup is very simple.
Program-controlled switches are programmed to operate on extension 8000. If you enter the correct code, there will be a confirmation tone and a beep. (If you don't have extension 8000, you can call 129 to check the physical number. 000 is the switchboard. )
First, find the function prefix of the program-controlled switch. Because the factory function prefix is "1", most of Chongqing is changed to "3". You can use125,225,325 to see if you can report the extension number. If 125 can report the extension number, it means that your function prefix has not changed. If all the prefixes "1" in the manual are changed to corresponding function prefixes.
Second, enter the programming state. First, on the 8000 switchboard, dial 18* and hang up. Note: If the prefix can be changed, the corresponding 18* will also be changed. For example, the function prefix is 3, which means 38* (Note! )
3. Enter the programming state (on the 8000 switch): dial 18*
1, the extension number is played (that is, the extension number is changed)
The code is: * 1 1* physical number * desired extension number #
The physical number can be queried by calling 129, and the required extension number cannot be the same as the existing number of the switch.
2, the extension level limit settings
1 class international and domestic calls, class 2 domestic calls, class 3 local calls, and class 6 local networks can only make internal calls.
* 10* grade * extension number #
3. Opening setting of extension caller ID: * 55 *1* # * 56 *1* # * 69 *1* #
4, relay perimeter opening settings
Open the article1:trk01:* 44 *1* 0/# via: *44*0*0 1#
Open the second perimeter TRK 02: * 44 * 1 * 02 # Pass: *44*0*02#
Open the third external line Trk03: * 44 * 1 * 03 # to connect: *44*0*03#
Open the fourth external line Trk04: * 44 * 1 * 04 # through: *44*0*04#
Open the fifth perimeter TRK 05: * 44 * 1 * 05 # Pass: *44*0*05#
Open the 06: * 44 * 1 * 06 # pass other than Article 6 TRK: *44*0*06#
5, since the input relay tone settings:
*5 1* 1065368 # Speak into the microphone after the beep. Audition: *5 1#, confirm *5 1* 1#.
6. Enter the relay mode selection setting.
Manual transfer: *06* 1* relay number # relay number: 0 1-04.
Voice prompt: *06*0* Relay number # Relay number: 0 1-04
Group call mode: *06*2* relay number # relay number: 0 1-04.
7, outside call mode selection settings
Manual transfer of outgoing calls: *06* 1* relay number # relay (external line) port number: 01-04 (0 1-08 for more than 48 doors)
Voice prompt for external call: *06*0* Relay number # Relay (external line) port number: 01-04 (0 1-08 for more than 48 doors)
Outside call mode: *06*2* Relay number # Relay (outside) port number: 01-04 (0 1-08 for more than 48 doors)
Description: The relay number refers to the external port number.
Outside call-in specified extension * 12* extension number * outside terminal number (0 1-08)#
For example, the company has three external access switches (the external port of the access switch is 0 1-03), and it is required to have a computer voice prompt for external calls, and dial 0 to the designated extension 8008 to check the number.
Setting code:
* 06 * 0 * 0 1 #, 06 * 0 * 02 #, 06 * 0 * 03 # (you can also set *06*0*0 1#02#03# continuously),
* 12*8008*0 1# (indicating that extension 8008 specified in 1 is dial 0 for directory search)
* 12*8008*02# (same as above)
* 12*8008*03# (ditto
8. The setting of powerpass prefix *57*A# A indicates the prefix to be set, and the default value is 1 (no setting is required).
9. Change the setting of the first number of the extension: *58*A# defaults to 8 (no need to change).
The setting of program-controlled switch has a great relationship with the brand and model of the switch. The above settings are general. Please refer to the instruction manual of SPC exchange for specific settings. ...& gt& gt
Question 8: How to set the telephone extension number? If you buy a telephone program-controlled exchange, several or dozens of telephones can form a telephone local area network. Plug the telephone access line into the switch and the extension telephone into the switch. Some switches can set the extension number freely, and some switches can't, but there is the extension number set by the switch on the opening where the extension phone is inserted.