How to set the landline switch?
Lead: The landline originally enjoyed a high status at home. Put it in a conspicuous position in the living room, and guests can see it as soon as they enter the door. Let me introduce you to the article on how to set the landline switch. Welcome to read the reference!

How to set up a landline exchange and how to set up a telephone exchange.

First, find the function prefix of the program-controlled switch. Because the factory function prefix is "1", most of Chongqing is changed to "3". You can use125,225,325 to see if you can report the extension number. If 125 can report the extension number, it means that your function prefix has not changed. If all the prefixes "1" in the manual are changed to corresponding function prefixes.

Second, enter the programming state. First, on the 8000 switchboard, dial 18* and hang up. Note: If the prefix can be changed, the corresponding 18* will also be changed. For example, the function prefix is 3, which means 38* (Note! )

3. Enter the programming state (on the 8000 switch): dial 18*

1, the extension number is played (that is, the extension number is changed)

The code is: * 1 1* physical number * desired extension number #

The physical number can be queried by calling 129, and the required extension number cannot be the same as the existing number of the switch.

2, the extension level limit settings

1 class international and domestic calls, class 2 domestic calls, class 3 local calls, and class 6 local networks can only make internal calls.

* 10* grade * extension number #

3. Opening setting of extension caller ID: * 55 *1* # * 56 *1* # * 69 *1* #

4, relay perimeter opening settings

Open the article1:trk01:* 44 *1* 0/# via: *44*0*0 1#

Open the second perimeter TRK 02: * 44 * 1 * 02 # Pass: *44*0*02#

Open the third external line Trk03: * 44 * 1 * 03 # to connect: *44*0*03#

Open the fourth external line Trk04: * 44 * 1 * 04 # through: *44*0*04#

Open the fifth perimeter TRK 05: * 44 * 1 * 05 # Pass: *44*0*05#

Open the 06: * 44 * 1 * 06 # pass other than Article 6 TRK: *44*0*06#

5, since the input relay tone settings:

*5 1* 1065368 # Speak into the microphone after the beep. Audition: *5 1#, confirm *5 1* 1#.

6. Enter the relay mode selection setting.

Manual transfer: *06* 1* relay number # relay number: 0 1-04.

Voice prompt: *06*0* Relay number # Relay number: 0 1-04

Group call mode: *06*2* relay number # relay number: 0 1-04.

7, outside call mode selection settings

Manual transfer of outgoing calls: *06* 1* relay number # relay (external line) port number: 01-04 (0 1-08 for more than 48 doors)

Voice prompt for external call: *06*0* Relay number # Relay (external line) port number: 01-04 (0 1-08 for more than 48 doors)

Outside call mode: *06*2* Relay number # Relay (outside) port number: 01-04 (0 1-08 for more than 48 doors)

Description: The relay number refers to the external port number.

Outside call-in specified extension * 12* extension number * outside terminal number (0 1-08)#

For example, the company has three external access switches (the external port of the access switch is 0 1-03), and it is required to have a computer voice prompt for external calls, and dial 0 to the designated extension 8008 to check the number.

Setting code:

* 06 * 0 * 0 1 #, 06 * 0 * 02 #, 06 * 0 * 03 # (you can also set *06*0*0 1#02#03# continuously),

* 12*8008*0 1# (indicating that extension 8008 specified in 1 is dial 0 for directory search)

* 12*8008*02# (same as above)

* 12*8008*03# (ditto

8. Setting *57*A# A for the power pass prefix means setting it. The default value is 1 (no setting is required).

9. Change the setting of the first number of the extension: *58*A# defaults to 8 (no need to change).

The setting of program-controlled switch has a great relationship with the brand and model of the switch. The above settings are general. Please refer to the instruction manual of SPC exchange for specific settings.

Extended reading: stored program control

Stored Program Control is to pre-store telephone information and the control, maintenance and management functions of switches into programs and store them in the memory of computers. When the switch works, the control part automatically monitors the state change of the phone and dials the number, and executes the program as required, thus completing various switch functions. Usually, this kind of switch belongs to all-electronic mode and adopts program-controlled mode, so it is called program-controlled switch, or telephone switch for short.

Telephone exchanges can be divided into local calls, long-distance calls and telephone exchanges according to their uses;

Telephone exchanges can be divided into space exchange and time exchange according to the connection mode.

Telephone exchanges can be divided into analog exchanges and private branch exchanges according to information transmission methods.