Current location - Quotes Website - Collection of slogans - What are the power operation and maintenance services?
What are the power operation and maintenance services?
First, 24-hour power emergency repair

Electric power emergency repair services such as fault detection, fault repair, hidden danger elimination, emergency power supply scheme, spare parts replacement and repair of all kinds of transmission, distribution and transformation equipment used by electric power enterprises (including: high and low voltage switchgear, power distribution cabinets, capacitor cabinets, metering cabinets, transformers, wires and cables, instruments and meters, comprehensive protection and other equipment).

The operator should maintain the equipment.

Second, the power supply maintenance, maintenance and safety inspection

1, power equipment maintenance

Power equipment maintenance services for all kinds of transmission, distribution and transformation power equipment used by power enterprises (including: high and low voltage switchgear, distribution cabinets, capacitor cabinets, metering cabinets, transformers, wires and cables, instruments and meters, comprehensive protection and other equipment).

2, power equipment maintenance, maintenance

Power equipment maintenance services for all kinds of transmission, distribution and transformation equipment used by power enterprises (including high and low voltage switchgear, distribution cabinets, capacitor cabinets, metering cabinets, transformers, wires and cables, instruments and meters, comprehensive protection and other equipment).

3, power equipment safety inspection

Power equipment safety inspection services (including: high and low voltage switchgear, power distribution cabinets, capacitor cabinets, metering cabinets, transformers, wires and cables, instruments and meters, comprehensive protection and other equipment) provide inspection and inspection, rectification suggestions and simple maintenance for the safety performance, numerical data detection, comprehensive protection, loop insulation and overall environmental safety hazards of power distribution of various transmission, distribution and transformation equipment used by power enterprises.

Third, the power equipment maintenance

Service scope: all kinds of transmission, distribution and transformation equipment used by power enterprises, and power custody services.

Service content:

1. Conduct routine inspection, testing and maintenance of electrical equipment entrusted by customers on a regular basis, and full-time patrol personnel will ensure that the equipment runs 24 hours a day.

2. Regularly clean, maintain and inspect the electrical equipment entrusted by customers.

3. Regularly evaluate the power factor of power consumption for customers, so as to ensure that users can save energy and electricity, and put forward technical transformation schemes for users with poor power quality and long-term unqualified power factor.

4. Establish the technical files of the managed equipment, and submit the monthly operation report of the customer's electrical equipment to the customer every month.

5, for the storage of electrical equipment and facilities, troubleshooting services.

6. Provide 24-hour emergency repair service for the stored electrical equipment and facilities.

7. Rectify the defects of the custody equipment proposed by the competent department of electric power in safety inspection.

8. Cooperate with the staff of the power supply company to conduct regular inspections on the running power equipment, lines and cables.

9, timely feedback to the customer found in the inspection of electricity problems and security risks, and put forward suggestions and solutions to customers, to ensure the long-term safety and economic use of electricity.

10, to assist customers to do a good job in safety prevention of electric shock and electrical fire.

1 1. According to customer requirements, provide customers with the best power consumption plan and fault emergency plan.

12, according to customer's requirements, carry out knowledge training on safe electricity use.

13. Provide power consulting services to other friends and users of customers according to their requirements.

14. Communicate the latest electricity consumption policy to customers.

Fourth, energy-saving renovation and maintenance.

1, reactive power optimization, improving power factor

Reactive power optimization transformation is mainly aimed at the technical transformation of insufficient reactive power compensation, unreasonable configuration of reactive power compensation equipment or damage of reactive power compensation equipment. Through reactive power optimization transformation, the loss of distribution system can be reduced, the power supply capacity of distribution system can be improved, the heating of distribution system can be reduced, the service life of distribution system can be prolonged, the reactive power punishment can be reduced or avoided, and the electricity expenditure can be reduced.

2, harmonic control, rectifier balance voltage

Harmonics can cause series resonance and parallel resonance, amplify harmonics, cause dangerous overvoltage or overcurrent, reduce the protection of transmission, transformation and distribution equipment, shorten the service life of accelerating power equipment and electrical equipment, and cause frequent failures and damages (such as computers, medical equipment, high-power important equipment, etc.). ); (2) The power distribution equipment (such as relay protection, comprehensive protection devices, instruments and meters, etc.) is not operating normally, or the switch (circuit breaker) that cannot operate normally is overloaded, resulting in frequent tripping; (3) Damage to reactive power compensation equipment parts, which can't make reactive power compensation, increase line loss and reduce rated capacity of transformer.

3. Line adjustment and load distribution

The technical transformation project of line transformation mainly aims at the problems of potential safety hazard, unreasonable line load, line heating, high electric loss, and inability to get up the compensation power factor. The wire diameter of (1) wire conductor is not proportional to the load. ② The line layout is irregular (the line is messy), or it is close to high temperature or inflammable and explosive places, and there is no reliable and effective safety protection measures. (3) The line is aging, and the insulation grade does not meet the requirements, so it should be improved according to the specific situation.