1. Division (sub-division) projects requiring intermediate acceptance: (1) Pile foundation, natural foundation, foundation treatment and other projects; (2) Foundation and foundation engineering (including underground waterproofing); (three) the main structure engineering (including concrete, steel, brick, wood and other stress structures); (4) Curtain wall engineering; (five) the elevator division project; (6) Sub-projects of building energy conservation; (7) Low-voltage power distribution (including generator set) installation project (8) related division (sub-division) projects confirmed by the construction, supervision unit or quality supervision institution according to the engineering characteristics and relevant regulations. Within 30 working days after completion, the construction unit shall conduct a comprehensive inspection of the project quality in accordance with the relevant national acceptance specifications and standards, sort out the technical data, fill in the application form for project quality acceptance of the division (sub-division), and submit it to the supervision unit for review together with the engineering technical data. 2, the supervision unit within 5 working days after the audit, at the same time in accordance with the relevant provisions of the physical inspection of the project, signed by the chief supervision engineer, together with the engineering technical data sent to the quality supervision institutions (supervisors) responsible for the project. 3, supervision institutions within 5 working days to spot check the engineering technical data, in the division (a branch) engineering quality inspection record form to fill in the data sampling opinions, and will notify the supervision unit in writing. 4. The supervision unit shall notify the relevant personnel of the survey, design, construction, construction and other units for acceptance, and shall notify the quality supervision institution (supervisor) to be present for acceptance supervision in advance. 5. After organizing the acceptance, the supervisor shall submit the "Division (Sub-Division) Project Quality Acceptance Record" and other relevant documents with complete signatures to the supervision station within 5 days, and go through the intermediate acceptance registration procedures for important division (Sub-Division) projects. 6, supervision institutions to meet the requirements of the division (a branch) in the middle of the project acceptance registration, and after signing the registration opinion and seal, the division (a branch) project quality acceptance record and the division (a branch) project quality acceptance registration form in triplicate, the construction unit, the construction unit and the archives each hold a copy. 7, division (a branch) engineering quality acceptance registration form is a necessary document for the unit project completion acceptance data, did not handle the important division (a branch) engineering intermediate acceptance registration formalities will be regarded as incomplete quality control data. Division (sub-division) project acceptance table is GB50300-200 1 appendix F.0. 1. Division (sub-division) project acceptance is more than the standard GBJ 300-88, which is a key point of quality control. Due to the increase of unit engineering quantity, complexity and professional construction units, in order to distinguish responsibilities and timely repair, the acceptance of division (sub-division) projects is more important. In the past, part of the unit project acceptance has been moved to the division (sub-division) project, in addition to the verification of the withdrawn project, there are also quality control data verification; Detection of safety and functional items; Visual quality acceptance, etc. The division (sub-division) project is completed by the construction unit, and the project manager reports it to the supervision unit or the construction unit for acceptance. The chief supervision engineer shall organize the construction project manager and the relevant survey (foundation and foundation) and design (foundation and foundation, main structure, etc.) project leaders. ) for acceptance, and make records according to the requirements in the table. Fill in the form: 1. Table name and header part 1. Table name: fill in the name of the division (sub-division) project in detail, write it in front of the division (sub-division) project, and cross out the division or sub-division respectively. 2. Fill in the full name of the project in the header, which is consistent with the project name of the inspection lot, subdivisional work and unit project acceptance sheet. Fill in the structure type provided according to the design documents. The number of floors should be marked underground and above ground respectively. The construction unit shall fill in its full name. And inspection lot. Sub-project. The name of the unit project acceptance sheet is the same. In most cases, the person in charge of the technical department and the person in charge of the quality department fill in the technical and quality person in charge of the project, only the foundation and foundation. The main structure and important installation division (sub-division) shall be the responsibility of the technical department and quality department of the construction unit. Subcontractor should be filled in only when there is a subcontractor, and should not be filled in when there is no subcontractor. The main structure shall not be subcontracted. The name of the subcontractor shall be written in full name, which is consistent with the name on the contract or seal. Person in charge of subcontractors and technical person in charge of subcontractors, and fill in the project person in charge and technical person in charge of this project. Second, the acceptance content, * * * has four contents: 1, subdivisional work. Fill in the name of subdivisional work according to the construction sequence of the first inspection lot of subdivisional work, fill in the actual inspection lot number of each subdivisional work in the second column, that is, the inspection lot number on the acceptance list of subdivisional work, and attach the evaluation form of each subdivisional work to the form in sequence. The construction unit shall check the evaluation column and fill in the self-inspection evaluation results of the construction unit. Check whether all subdivisional work is qualified, and whether the qualification evaluation of aging specimens meets the requirements; The inspection items of total height verticality or total elevation shall be inspected and accepted. If the self-inspection meets the requirements, mark it with "/",otherwise mark it with "X". The project marked with "X" cannot be submitted to the supervision unit or the construction unit for acceptance, so it should be repaired and submitted for acceptance after it is qualified. The supervision unit or the construction unit shall be reviewed by the chief supervision engineer or the project professional and technical person in charge of the construction unit. After meeting the requirements, sign the "Agree to Accept" opinion in the acceptance opinion column. 2. Quality control data. The quality control data items of the accepted division (sub-division) project shall be determined according to the relevant contents of the unit (sub-unit) project quality control data verification record in GB 50300-2001+0 table G.0. 1-2, and shall be checked item by item according to the requirements of data verification. Can basically reflect the quality of the project, meet the requirements of ensuring structural safety and use function, and then pass the acceptance. If all the projects are qualified, you can mark "/"in the inspection and evaluation column of the construction unit as qualified. And send it to the supervision unit or the construction unit for acceptance, and the chief supervision engineer of the supervision unit will organize the review. After meeting the requirements, endorse the "Agree to Accept" opinion in the acceptance opinion column. Some projects can be accepted by sub-division projects, and some projects can be accepted by division projects. Because the projects are different, there is no need for unification. 3, safety and function inspection (inspection report, this project refers to the completion of sampling inspection project, can be detected in the division (a branch) project, as far as possible in the division (a branch) project detection. The inspection contents shall be determined according to the relevant contents in the data verification of engineering safety and function inspection of unit (subunit) G.0. 1-3 in table GB 50300-2001+0 and the random inspection records of main functions. In the process of verification, we should pay attention to whether all the projects determined before construction have passed the inspection; Check each test report one by one, and check whether the test methods and procedures of each test item meet the relevant standards; Whether the test results meet the specification requirements. Whether the signature of the examination and approval procedures of the test report is complete. Indicate the approval on each report. After each inspection item is qualified, it can be marked with "V" in the inspection and evaluation column of the construction unit. The project manager sends it to the supervision unit or the construction unit for acceptance, and the chief supervision engineer of the supervision unit or the project professional director of the construction unit organizes the review. After meeting the requirements, sign the "Agree to Accept" opinion in the acceptance opinion column. 4, visual quality acceptance. In fact, it is not only the appearance quality, but also what can be started or put into trial operation, and what can be opened depends on it. Representative rooms and parts shall be visited, and on-site inspection shall be organized by the project manager of the construction unit. After passing the inspection, the contents filled in by the construction unit shall be filled in and signed by the project manager and submitted to the supervision unit or the construction unit for acceptance. The supervision unit shall be accepted by the chief supervision engineer of the construction unit or the person in charge of the project. On the basis of listening to the inspectors' opinions, the quality evaluation shall be determined by the chief supervision engineer or project professional director of the construction unit, and the good, average and poor shall be signed by the project manager and chief supervision engineer or project professional director of the construction unit. If you evaluate items with poor visual quality, try to repair them. If it is really difficult to repair, as long as it does not affect the structural safety and use function, it can be negotiated and accepted, and marked on the acceptance form, and then the acceptance evaluation conclusion can be filled in the section (sub-section) project visual quality acceptance opinion column. Three, the acceptance unit signature recognition. According to the list, the relevant personnel involved in the project construction responsibility unit should sign in person to show their responsibility, so as to trace the quality responsibility. The survey unit can only sign and recognize the foundation division (sub-division) project, and the person in charge of the project personally signs and recognizes it; The design unit can only sign the foundation, main structure, important installation division (sub-division) project, and the project leader personally signs it; The general contract of the construction unit must be signed, and the project manager must personally sign. Subcontractors with subcontractors must also sign off on their subcontracted division (sub-division) projects, and the subcontracting project manager must sign off in person. As the acceptance party, the supervision unit shall be personally signed and accepted by the chief supervision engineer. If the project is not entrusted to the supervision unit according to the regulations, the professional person in charge of the project of the construction unit may personally sign and accept it.