(1) system component installation
Selection and inspection of main equipment such as unit door host, indoor visual intercom extension, non-visual intercom extension, communication converter, networking equipment, interlayer distributor and management center machine. , and install the above devices in a reasonable position in the corresponding area according to the requirements of the drawings.
(2) System wiring
Complete the wiring and connection of visual intercom access control.
(3) System debugging
Set the relevant parameters of intercom access control system, complete the address setting of outdoor host, indoor extension, IC card distribution and registration, management center machine setting, etc. And realize the functions of outdoor host calling indoor extension, indoor extension calling management center machine, outdoor host calling management center machine, password unlocking, indoor extension active unlocking, card swiping unlocking, visual intercom software information recording, etc.
2. Video monitoring system
(1) system component installation
Selection and detection of high-speed spherical pan-tilt camera, color hemisphere camera, gun camera, infrared camera, matrix host, hard disk video recorder and other equipment, and install them in a reasonable position in the corresponding area according to the requirements of drawings.
(2) System wiring
Complete the wiring and connection of the video surveillance system.
(3) System setup and debugging
By setting the system parameters, the video monitoring and picture switching of the monitor, high-speed spherical pan-tilt rotation, focusing action control and alarm linkage video recording are realized.
3. Indoor security and perimeter prevention system
(1) system component installation
Selection and detection of vibration detector, glass broken detector, temperature detector, smoke detector, combustible gas detector, infrared detector, door magnet, infrared counting detector, audible and visual alarm, alarm button, infrared curtain detector, large alarm host, six-zone alarm host, LCD keyboard, multi-channel bus driver, etc. , and installed in a reasonable position in the corresponding area according to the requirements of the drawings.
(2) System wiring
Complete the wiring and connection of indoor security and perimeter prevention system.
(3) system programming and debugging
Through the system parameter setting, the alarm of indoor security and perimeter prevention is realized, and the alarm processing is carried out.
4. Patrol system
(1) system component installation
Install the information point according to the drawing requirements.
(2) System debugging
Through the parameter setting of the system, the circuit setting of the patrol system, the statistics of patrol data and the generation of reports are realized. 1. Competition venue
Building intelligent competition venues are designed in 60 ~ 65 groups, with an area of 1200m2.
2. Equipment description
The competition equipment adopts THBCAS-2 building intelligent security wiring training system (Tianhuang teaching instrument) developed by Zhejiang Tianhuang Technology Industry Co., Ltd., and the consumables are provided uniformly.
(1) Basic specification number Equipment name Equipment specification or model number unit 1 Building model consists of aluminum alloy profile frame and mesh board for installation and wiring, 3120mm×1580mm× 2310mm (length× width× height), which is divided into intelligent. 1 set of two computer desks 600mm×600mm×800mm (length× width× height) 1 set of three steel benches φ300mm×450mm (circle× height) 1 set of four aluminum ladders 900 mm× 250 mm×/kloc-0. 5 Engineering plastic card 20mm×10mm×11mm (length× width× height) 300 6-machine mainstream brand computers, provided by users, with built-in operating system and intercom access control software. Indoor security software 1 set (ii) system configuration serial number name configuration content remarks 1 intercom access control system includes color visual outdoor host, ordinary wall-mounted indoor extension, management center machine, networking equipment, interlayer distributor, communication conversion module, management software and contactless card. The video monitoring system includes high-speed ball camera, color hemisphere camera, infrared camera, bolt machine, matrix host, hard disk video recorder and monitor. Indoor security and perimeter protection system includes vibration detector, glass breakage detector, temperature detector, smoke detector, combustible gas detector, infrared detector, door magnet, infrared correlation detector, audible and visual alarm, alarm button, infrared curtain detector, large alarm host, six-zone alarm host, LCD keyboard, multi-channel bus driver and RS232 printer interface module. Patrol system includes patrol system, communication line, charger and information button. Fourth, tools
The Games will provide tools, mainly including:
(1) Tools for connecting circuits: screwdriver, wire stripper, needle-nosed pliers, oblique-nosed pliers, scissors, soldering iron, solder wire, tweezers, etc. Electric screwdrivers and pneumatic screwdrivers are not allowed.
(2) Circuit and device inspection tool: multimeter.
(3) Test question answering tools: ballpoint pen or signature pen, HB and B pencils, eraser and triangular ruler.
(4) Measuring tool: 3m tape measure or soft ruler. 1. The names of the teams participating in the competition shall be the names of the regional teams, and the names of schools or other organizations or groups shall not be used; Cross-school team registration is not accepted.
2. After the registration is verified, the team members will not be replaced in principle. If the team members are unable to participate in the competition for some reason during the preparatory process, the local provincial education department shall issue a written explanation and supplement the personnel according to the relevant regulations for review; After the start of the game, the participating teams are not allowed to change their players and are allowed to be absent from the game.
3. Contestants must report at the scene and enter the competition venue according to the time specified by the General Assembly.
Contestants must bring two certificates (ID card and student ID card) together with their badges. No one is allowed to take part in the competition.
5. The dress of the contestants must meet the requirements of safety production and competition.
6. If the contestants are late for more than 15 minutes, they will not be allowed to enter the stadium again and will be treated as abstaining. Players are not allowed to leave for half an hour after the game starts.
7. Drinking water and going to the toilet are counted in the competition time. Except for normal drinking, all other activities unrelated to the competition need to be signaled to the referee on duty and allowed by the referee.
8. The game needs to last. Once the game starts, it can't be terminated without reason. If there is a non-human fault in the equipment during the competition, which makes it impossible to continue the competition, the competition can be postponed subject to the confirmation and approval of the chief referee (or deputy referee), and the delay time shall be subject to the troubleshooting time of the equipment.
9. Players shall participate in the competition in a civilized manner, and shall not interfere with the competition of other teams, and shall not leave the designated area of the competition without authorization.
10. After the game, players are not allowed to do any more operations. Teams that finish the game early must be signed by the players and the referee before they can leave and enter the designated area. (1) Complaint
1. The team can complain about the equipment and tools that do not meet the competition regulations, unfair referees and rewards, and staff violations.
2. Complaints should be made within 2 hours after the end of the competition, and will not be accepted after the deadline. When appealing, the team leader shall submit a written appeal report to the referee Committee of the corresponding project according to the prescribed procedures. The report shall give a comprehensive and true description of the phenomenon, occurrence time, personnel involved, basis and reasons of the complaint. Complaints with insufficient factual basis and only subjective assumptions will not be accepted. The complaint report must be signed by the complaining player and the team leader.
3. After receiving the complaint report, the tournament referee committee shall review the complaint according to the reasons, and notify the complainant in writing within 6 hours to inform the complaint handling result. When accepting a complaint, it shall inform the complainant of the time and place of the hearing; If the complaint is not accepted, the reasons shall be explained.
4. The complainant shall not refuse to accept the result without reason, and shall not take excessive actions to make things difficult or attack the staff, otherwise it shall be regarded as giving up the complaint. If the complainant refuses to accept the result of the arbitration commission, he may apply to the technical advisory committee of competition experts for reconsideration.
(2) Arbitration
1.20 10 The Expert Technical Advisory Committee of the National Skills Competition for Vocational Colleges is responsible for accepting complaints, reconsideration and arbitration, so as to ensure the smooth progress of the competition and the fairness and justice of the results.
2. The decision of the Expert Technical Advisory Committee is final. Each team shall not stop the game or make trouble because they are not satisfied with the arbitration opinion, otherwise it will be treated as abstention. Exam Outline of "Tianhuangbei" Intelligent Building (Security Wiring Debugging) Project Competition
First, the knowledge requirements and ability requirements of the competition examination content
1. knowledge requirements
Knowledge refers to the relevant knowledge about security and wiring of intelligent buildings in the teaching content specified by building intelligence or other related majors in secondary vocational schools.
The requirements for knowledge are two levels in turn: understanding, understanding and mastering.
(1) Understanding: It is required to have a preliminary perceptual understanding of the meaning and background of the listed knowledge, and know what this knowledge content is, which can (or will) be identified in related issues.
(2) Comprehension and mastery: It is required to have a profound theoretical understanding of the listed knowledge, be able to explain, give examples or make inferences, and use knowledge to solve related problems.
2. Capability requirements
Ability refers to the ability of drawing recognition, installation and debugging, specification application and site design.
(1) Be able to read drawings and understand design intent.
(2) Installation and debugging ability: the construction is carried out correctly according to the drawings, and the installation meets the specification requirements, so that mistakes in design can be found.
(3) Specification application ability: it can be installed and constructed according to the requirements of relevant specifications.
(4) Site design capability: Determine the installation location and wiring path of the equipment according to the specific conditions of the site.
Second, the scope and specific content of the examination
1. intercom access control system
(1) map reading
(2) Install intercom access control system components
(3) Wiring of intercom access control system
(4) Setup, debugging and operation of intercom access control system
2. Video monitoring system
(1) map reading
(2) Install video monitoring system components.
(3) video monitoring system wiring
(4) Setting, debugging and running of video monitoring system
3. Indoor security and perimeter prevention system
(1) map reading
(2) Installation of indoor safety and perimeter prevention system components
(3) Wiring of indoor security and perimeter prevention system
(4) Setup, debugging and operation of indoor security and perimeter prevention system
4. Patrol system
(1) map reading
(2) Install patrol system components
(3) Debugging and running of inspection system
Reference specification:
Code for Quality Acceptance of Building Electrical Construction GB50303-2002
Design Standard for Intelligent Buildings GB/T503 14-2006
Code for Quality Acceptance of Intelligent Building Engineering GB50339-2003
Technical Specification for Safety Prevention Engineering (GB50348-2004)
Code for Engineering Design of Intrusion Alarm System (GB50394-2007)
Code for Engineering Design of Video Security Monitoring System (GB50395-2007)
Code for Engineering Design of Access Control System (GB50396-2007)